File: src/main.zig:642-647
Severity: MEDIUM
Status: ✅ FIXED
SIGWINCH was configured with SA_RESTART, preventing blocking system calls from returning EINTR on terminal resize signals.
Setting SA_RESTART flag on SIGWINCH sigaction setup.
Set flags = 0 on SIGWINCH sigaction so blocking I/O calls return EINTR immediately on resize.
Client display redraws on window resize are delayed until another event occurs.